Diametral tensile strength of novel fast-setting calcium silicate cement
Bahram RANJKESHFlemming ISIDORMichel DALSTRAHenrik LØVSCHALL
Author information
JOURNAL FREE ACCESS

2016 Volume 35 Issue 4 Pages 559-563

Details
Abstract

Novel fast-setting calcium silicate cement with fluoride (CSC) has been developed for potential applications in tooth crown. The aim of this study was to test the diametral tensile strength (DTS) of different CSC compositions in humid condition on day1, 28, and 180. We tested ‘bond CSC’ with 3.5% fluoride and no radiocontrast, ‘CSC’ with 3.5% fluoride and 10% radiocontrast, ‘ultrafast CSC’ with 3.5% fluoride and 20% radiocontrast, ‘high fluoride CSC’ with 15% fluoride and 25% radiocontrast, Biodentine, and MTA. We filled the cements after mixing to cylindrical molds. Specimens were stored in >95% humidity. DTS was measured at each time point. CSC compositions had statistically higher DTS compared to MTA and Biodentine on day1. Bond CSC showed higher DTS versus all cements, except CSC, at all time points. DTS of all cements, except Biodentine, significantly increased in humid condition on day28 and day180 compared to day1.

Content from these authors
© 2016 The Japanese Society for Dental Materials and Devices