Effect of polymerization cycles on flexural strengths and microhardness of different denture base materials
Hasan GUNGORMustafa GUNDOGDUMurat ALKURTZeynep YESIL DUYMUS
Author information
JOURNAL FREE ACCESS

2017 Volume 36 Issue 2 Pages 168-173

Details
Abstract

The purpose of this study was to evaluate the effect of different polymerization cycles on the flexural strengths and microhardness of two denture base materials (Meliodent and Paladent). Heat-polymerized acrylic resin specimens (65.0 mm long×10.0 mm wide×2.5 mm in height) were prepared using different short and long polymerization cycles. After the specimens had been polymerized, they were stored in distilled water at 37±1°C for 24 h. Flexural strength test was performed at a cross-head speed of 5 mm/min and Vickers microhardness was measured. Data were analyzed with a 1-way analysis of variance followed by Tukey test, and Student t-test (α=0.05). The flexural strengths and microhardness were significantly different between Meliodent and Paladent (p<0.05). Significant differences were found among the polymerization cycles in terms of flexural strengths and microhardness (p<0.05). Polymerization with G cycle may be suggested for Meliodent and H cycle may be suggested for Paladent.

Content from these authors
© 2017 The Japanese Society for Dental Materials and Devices
Previous article Next article