Dental Materials Journal
Online ISSN : 1881-1361
Print ISSN : 0287-4547
ISSN-L : 0287-4547
Original Paper
Effects of various etching protocols on the flexural properties and surface topography of fiber-reinforced composite dental posts
Juthatip AKSORNMUANGChanya CHUENARROMNatjira CHITTITHAWORN
Author information
JOURNAL FREE ACCESS

2017 Volume 36 Issue 5 Pages 614-621

Details
Abstract

The purpose of this study was to evaluate the flexural properties and surface topography of fiber posts surface-treated with various etching protocols. Seventy each of three types of fiber posts: RelyX Fiber Post, Tenax Fiber Trans, and D.T. Light-Post Illusion X-Ro, were randomly divided into 7 groups: no surface treatment, surface treated with hydrofluoric acid (HF) 4.5% for 60 s, HF 4.5% for 120 s, HF 9.6% for 15 s, HF 9.6% for 60 s, HF 9.6% for 120 s, and treated with H2O2 24% for 10 min. The specimens were then subjected to a three-point bending test. Surface topographies of the posts were observed using a SEM. The results indicate that fiber post surface pretreatments had no adverse effects on the flexural properties. However, the fiber posts treated with high HF concentrations or long etching times seemed to have more surface irregularities.

Content from these authors
© 2017 The Japanese Society for Dental Materials and Devices
Previous article Next article
feedback
Top