Dental Materials Journal
Online ISSN : 1881-1361
Print ISSN : 0287-4547
ISSN-L : 0287-4547
Original Paper
Influence of grade and surface topography of commercially pure titanium on fatigue properties
Kaoru SUZUKITomofumi TAKANOShinji TAKEMOTOTakayuki UEDAMasao YOSHINARIKaoru SAKURAI
Author information
JOURNAL FREE ACCESS

2018 Volume 37 Issue 2 Pages 308-316

Details
Abstract

The objective was to investigate the influence of grade and surface topography of commercially pure titanium (Cp-Ti) on fatigue properties evaluated via staircase method. Cp-Ti grades 2 and 4 were roughened by shot blasting and acid etching, and compared with machined specimens. Yield force under static loading for Cp-Ti grades 2 and 4 were 672±51 and 1,088±93 N for machined and 724±99 and 1,118±96 N for roughened group. Yield force under cyclic loading for Cp-Ti grades 2 and 4 decreased 27 and 40% compared to static loading. Cp-Ti grade 4 demonstrated significantly greater decrease in yield force after cyclic loading; however surface topography had no effect.

Content from these authors
© 2018 The Japanese Society for Dental Materials and Devices
Previous article Next article
feedback