Dental Materials Journal
Online ISSN : 1881-1361
Print ISSN : 0287-4547
ISSN-L : 0287-4547
Original Paper
Early bond strengths of 4-META/MMA-TBB resin cements to CAD/CAM resin composite
Junichi SHINAGAWAGo INOUEToru NIKAIDOMasaomi IKEDAMichael F. BURROWJunji TAGAMI
Author information
JOURNAL FREE ACCESS

2019 Volume 38 Issue 1 Pages 28-32

Details
Abstract

The purpose of this study was to evaluate the early tensile bond strengths of three different resin cements; Super Bond C&B (conventional and quick type) and ResiCem to a CAD/CAM composite block. A CAD/CAM composite block (Shofu Block HC) was ground and silanized according to the manufacturers’ instructions before cementation. A conventional tensile bond strength test (Ø: 4 mm) was performed 10 min, 1 h and 24 h after bonding. Super Bond C&B (quick type) showed the highest bond strength at 24 h. However, results of a three-point bend test showed the mechanical properties were weaker for the Super Bond C&B cements compared with composite cement, Resicem. The 4-META/MMA-TBB resin is a suitable resin cement to bond to a CAD/CAM composite block.

Content from these authors
© 2019 The Japanese Society for Dental Materials and Devices
Previous article Next article
feedback
Top