2020 Volume 39 Issue 3 Pages 429-434
This study aimed to evaluate the effects of artificial saliva contamination on a glass ionomer cement (GIC), a resin-modified GIC (RMGIC), and a composite resin (CR) that was used with two different etching adhesive systems. Three surface conditions were created on bovine teeth using artificial saliva: control (group I), mild saliva contamination (group II), and severe saliva contamination (group III). The microtensile bond strength (μTBS) of CR with dentin was significantly lower in group III than in group I. However, the μTBS of GIC and RMGIC with both enamel and dentin showed no significant intergroup differences. Moreover, CR exhibited significantly greater microleakage on cementum in group III than in group I, whereas both GIC and RMGIC showed no significant differences for both enamel and cementum. Thus, GIC and RMGIC may be suitable for preventing secondary caries after class V restorative treatments when contamination by saliva cannot be avoided.