This study tested and compared properties of six modern indirect veneering resin composites (VRC), namely Ceramage (Shofu), dialog Vario (Schütz Dental), Gradia Plus (GC Europe), in:joy (Dentsply), Signum composite (Heraeus Kulzer), and SR Nexco (Ivoclar Vivadent). Specimens were fabricated from dentin and enamel pastes and following properties were analyzed: (1) two-body wear (TB), (2) surface roughness (SR), (3) Martens hardness parameters (HM and EIT), and (4) translucency (T). The highest impact on HM and EIT was exerted by VRC brand (HM: ηP2=0.960/ EIT: ηP2=0.968; p<0.001), followed by VRC paste material (HM: ηP2=0.502/ EIT: ηP2=0.580; p<0.001), and aging duration (HM: ηP2=0.157/ EIT: ηP2=0.112; p<0.001). Lowest and highest TB were measured for Signum composite and dialog Vario, respectively (p<0.001). Highest T was showed Signum composite and Ceramage (p<0.001). VRCs should be individually selected with respect to the indication area, due to different surface properties.