Dental Materials Journal
Online ISSN : 1881-1361
Print ISSN : 0287-4547
ISSN-L : 0287-4547
Original Paper
In-vitro performance of posterior fiber reinforced composite (FRC) bridge with different framework designs
Yee ANGChee Ghuan TANNorziha YAHAYA
Author information
JOURNAL FREE ACCESS

2021 Volume 40 Issue 3 Pages 584-591

Details
Abstract

This study aimed to investigate the effect of various framework designs on the failure of posterior fiber reinforced composite (FRC) bridges and assess the post crack performances of the repaired prostheses. Thirty samples were prepared into three different groups of framework designs: cuspal support (CS), anatomic features (AF) and circular reinforcement (CR). All specimens were subjected to static loading test and acoustic emission analysis. Significant differences were found in the load and time of initial failures among the three groups (p<0.001). CS was identified as the optimum framework design. Samples with composite delamination at the pontic site were selected and repaired with a clinically simplified protocol. Significant differences were also observed between the repaired and original FRC bridges (p=0.01). The performance of these prostheses was highly dependent on the framework design and the perspective of repairing FRC bridges may warrant future investigations.

Content from these authors
© 2021 The Japanese Society for Dental Materials and Devices
Previous article Next article
feedback