Can polylactic acid be a CAD/CAM material for provisional crown restorations in terms of fit and fracture strength?
Merve BENLİBeril EKER-GÜMÜŞYusuf KAHRAMANOlivier HUCKMutlu ÖZCAN
Author information
JOURNAL FREE ACCESS

2021 Volume 40 Issue 3 Pages 772-780

Details
Abstract

This study aimed to evaluate polylactic acid (PLA) as a provisional crown material. Lower right first molar phantom tooth was used for the fabrication of 60 crowns. Samples were divided into three groups (n=20) according to the material: Group PL (PLA), Group PM (polymethyl methacrylate), and Group PE (polyetheretherketone). Each group was investigated for internal and marginal fit, fracture strength, and fracture mode. Data were analyzed using ANOVA, chi-squared test, and Tukey’s tests (p≤0.05). The average marginal gap value of each group was: PE 56.00±4.67 µm, PM 61.15±4.44 µm, and PL 60.40±2.85 µm (p<0.001). The average internal gap value for each group was: PE 128.90±8.39 µm, PM 132.40±7.51 µm, and PL 130.75±9.76 µm (p=0.442). The average fracture strength of each group was: PE 840.90±13.23 N, PM 733.30±9.00 N, and PL 664.50±10.79 N (p<0.001). Results demonstrated that PLA may be a good option as a provisional crown material.