Dental Materials Journal
Online ISSN : 1881-1361
Print ISSN : 0287-4547
ISSN-L : 0287-4547
Original Paper
Simultaneous detection of monomers associated with resin-based dental composites using SPME and HPLC
Gabriella KAKONYISteven MULLIGANAndrew W. FAIRBURNKeyvan MOHARAMZADEHSteven F. THORNTONHeather J. WALKERMike M. BURRELLNicolas MARTIN
Author information
JOURNAL FREE ACCESS

2021 Volume 40 Issue 4 Pages 1007-1013

Details
Abstract

As resin-based composites (RBC) replace dental amalgam for environmental reasons, there is a requirement to understand the environmental impact of this alternative dental restorative material. In this study we standardize the simultaneous detection of five monomeric components associated with RBCs using high performance liquid chromatography (HPLC) coupled with solid-phase microextraction (SPME). Factors affecting method performance (detection wavelength, calibration conditions, method sensitivity/accuracy/precision, extraction time/efficiency) are evaluated using standard solutions containing the mixture of TEGDMA, UDMA, Bis-GMA, BPA and HEMA. Detection sensitivity and analytical efficiency of the method is optimized for these compounds using 200 nm detection wavelength, PDMS/DVB fiber and extraction time of 90 min. Analytical accuracy of the HPLC is >95% for all monomers, with precision of 2.3–5.1%. Detection limits under the conditions described are 25 µg/L for HEMA, BPA, UDMA, Bis-GMA, and 100 µg/L for TEGDMA. The extraction time is governed by the largest molecular weight compounds.

Content from these authors
© 2021 The Japanese Society for Dental Materials and Devices
Previous article Next article
feedback
Top