Dental Materials Journal
Online ISSN : 1881-1361
Print ISSN : 0287-4547
ISSN-L : 0287-4547
Original Paper
CAD/CAM lithium disilicate ceramic crowns: Effect of occlusal thickness on fracture resistance and fractographic analysis
Carlos A. JURADOFrancisco PINEDODaniel Alberto CORTES TREVINOQuotasze WILLIAMSAlberto MARQUEZ-CONDEMasao IRIEAkimasa TSUJIMOTO
Author information
JOURNAL FREE ACCESS

2022 Volume 41 Issue 5 Pages 705-709

Details
Abstract

This study uses fracture tests and fractographical analysis to compare computer-aided design and computer-aided manufacturing (CAD/CAM) lithium disilicate molar crowns with the previous occlusal thickness recommendation of 1.5-mm, the new recommendation of 1.0-mm, and a less invasive thickness of 0.8-mm. After fatigue application, fracture tests and fractographic analysis were conducted. The fracture resistance of CAD/CAM lithium disilicate molar crowns was different depending on the occlusal thickness of the restoration, and decreased with lower the thickness. However, the fracture resistance of crowns of all three thicknesses exceeded the reported maximum bite force in the first molar region after the fatigue process, and can be considered acceptable for use in the clinic.

Content from these authors
© 2022 The Japanese Society for Dental Materials and Devices
Previous article Next article
feedback
Top