Dental Materials Journal
Online ISSN : 1881-1361
Print ISSN : 0287-4547
ISSN-L : 0287-4547
Original Paper
Evaluation of the machinability and machining accuracy of polymer-based CAD/CAM blocks using merlon fracture test model
Chang-Sub JEONGJoon-Mo MOONHee-Jeong LEEJi-Myung BAEEun-Joo CHOISung-Tae KIMYoungbum PARKSeunghan OH
Author information
JOURNAL FREE ACCESS

2023 Volume 42 Issue 2 Pages 273-281

Details
Abstract

The aims of this study were to estimate the machinability and machining accuracy of polymer-based CAM blocks using the merlon fracture test model specified in ISO 18675: 2022. Three hybrid disc blanks (MazicDuro, HC Disk, and Enamic) and three polymethyl methacrylate (PMMA) disc blanks (PMMA Disk, PMMA Block, and MazicTemp Hybrid) were tested in this study. The machinability was evaluated by assigning scores according to the fracture range of merlons with areas divided by ten vertical planes. The machining accuracy was evaluated by superimposing methods via CAD reference data and CAD specimen data. Within the limits of this study, a thickness of 0.3 mm is recommended for the clinical application of polymer-based CAD/CAM blocks in dental restorations that require superior machinability and accuracy. In addition, the machinability and machining accuracy tests of polymer-based CAM blocks are expected to provide guidelines for preparing accurate dental restorations.

Content from these authors
© 2023 The Japanese Society for Dental Materials and Devices
Previous article Next article
feedback