Surface and intra-pulpal temperature variation during tooth whitening photoactivated with LED/laser
Joatan Lucas de Sousa Gomes COSTAMariana Bena GELIOLucas David GALVANIJoão Felipe BESEGATOEster Alves Ferreira BORDINIEduardo Fernández GODOYLuis Geraldo VAZMilton Carlos KUGA
Author information
JOURNAL FREE ACCESS

2023 Volume 42 Issue 5 Pages 654-658

Details
Abstract

This study evaluated the variation of surface and intra-pulpal temperature, during bleaching protocol, using LED/laser. The 35% (HP35), 15% (HP15) and 6% (HP6) gels were used associated with LED/laser applied every 1 min for 30 min in a human canine. The evaluation of surface temperature variation (∆Ts) was performed using a pHmeter and the intra-pulpal temperature variation (∆Ti) was performed using a digital thermometer, at times of 1-, 5-, 10- 15- and 30-min. Statistical analysis was performed using the two-way repeated measures ANOVA test and Bonferroni post-hoc test was used at a significance level of 5%. HP35 and HP15 showed greater temperature variation than HP6 up to 10 min of surface evaluation, showing no differences between them. In the intra-pulpal evaluation, no group showed differences throughout the procedure.