Dental Materials Journal
Online ISSN : 1881-1361
Print ISSN : 0287-4547
ISSN-L : 0287-4547
Original Paper
Scanning electron microscopy observation of dentin bond interfaces in different types of resin luting cements
Toshiki TAKAMIZAWARyota AOKIKana HAYASHIMone SHOJIYuta KASAHARAWayne W. BARKMEIERMark A. LATTAAtsushi KAMIMOTOMasashi MIYAZAKI
Author information
JOURNAL FREE ACCESS

2024 Volume 43 Issue 2 Pages 179-190

Details
Abstract

This study aimed to observe and compare the resin luting cement (RLC)/dentin interfaces of different types of RLC systems with scanning electron microscopy (SEM). This study evaluated six self-adhesive resin luting cement systems (SARLCs), four systems combining a SARLC with a tooth primer (SARLCPs), and six conventional resin luting cement systems (CVRLCs). Cured resin composite rods were bonded to bovine dentin using RLCs in different etching modes. The morphological features at the interfaces were observed using SEM. Although all RLCs in etch-&-rinse (ER) mode showed a clear hybrid layer, most SARLCs had a thinner and more porous hybrid layer than the SARLCPs and CVRLCs. All SARLCPs with primer and CVRLCs showed a thin high-density layer below the primer layer in both etching modes. CVRLCs and SARLCPs with primer treatment systems may be more versatile and reliable when compared to simplified RLC systems.

Content from these authors
© 2024 The Japanese Society for Dental Materials and Devices
Previous article Next article
feedback
Top