Influence of resin-coating techniques on the marginal adaptation and the bond strengths of CAD/CAM-fabricated hybrid ceramic inlays
Yuna KANAMORIRena TAKAHASHIToru NIKAIDOHiroshi NITTAYasushi SHIMADAJunji TAGAMIKarl-Heinz KUNZELMANN
著者情報
ジャーナル オープンアクセス

2024 年 43 巻 3 号 p. 407-414

詳細
抄録

This study aimed to evaluate the effects of different resin-coating technique strategies and dual-cure resin luting materials on proximal marginal adaptation and the microtensile bond strengths (μTBSs) of CAD/CAM hybrid ceramic inlays. Extracted human molars were classified into four groups, depending on the coating technique: No coating (None), single coating (1-coating), double coating (2-coating), and flowable resin-coating (Combination). The inlays were bonded with one of the three materials: Panavia V5 (V5), Rely X Ultimate (RXU), and Calibra Ceram (CC). The differences with regard to adaptation were not significant. In the case of μTBS data for V5, no significant differences were observed, whereas for RXU, μTBS values for Combination statistically exceeded those for None and 1-coating. For CC, μTBS values for Combination statistically exceeded those for None, 1-coating, and 2-coating. The coating techniques did not influence the adaptation but influenced the bond strength, and Combination performed the best.

著者関連情報
© 2024 The Japanese Society for Dental Materials and Devices

This is an open access article under the CC BY license
https://creativecommons.org/licenses/by/4.0/