Dental Materials Journal
Online ISSN : 1881-1361
Print ISSN : 0287-4547
ISSN-L : 0287-4547

この記事には本公開記事があります。本公開記事を参照してください。
引用する場合も本公開記事を引用してください。

Transformation behavior of nickel-titanium orthodontic wires under tensile load
Masahiro IIJIMAMitsuru OHTAWilliam A. BRANTLEYAtsuko NAGANISHITakashi MURAKAMITakeshi MUGURUMAItaru MIZOGUCHI
著者情報
ジャーナル フリー 早期公開

論文ID: 2010-196

この記事には本公開記事があります。
詳細
抄録
This study investigated transformations of nickel-titanium wires using differential scanning calorimetry (DSC) and thermomechanical analysis (TMA) under tensile load (100 gf or 500 gf). Two nickel-titanium wires, 35°C Copper Ni-Ti and Nitinol SE, were selected. DSC analyses were performed between –90° and 100°C. Specimens prepared for TMA were approximately 150 μm thick and 12 mm long. TMA analyses were performed between –120° and 100°C. With TMA, all transformation temperatures for a tensile load of 500 gf, obtained from both the heating and cooling curves, were higher than those for a tensile load of 100 gf. While mean As and Af temperatures for Copper Ni-Ti obtained by TMA were much higher than those obtained by DSC analysis, mean Ms and Mf temperatures obtained by TMA were much lower than those obtained by DSC analysis. The transformation behavior of nickel-titanium wires with change in temperature was affected by application of tensile load.
著者関連情報
© 2011 The Japanese Society for Dental Materials and Devices
feedback
Top