Dental Materials Journal
Online ISSN : 1881-1361
Print ISSN : 0287-4547
ISSN-L : 0287-4547

This article has now been updated. Please use the final version.

Comparison between direct chairside and digitally fabricated temporary crowns
Adil O. ABDULLAHSarah POLLINGTONYi LIU
Author information
JOURNAL FREE ACCESS Advance online publication

Article ID: 2017-315

Details
Abstract

The mechanical properties of temporary crowns are considered to be crucial in order to achieve successful definite restorations. This study compared marginal fit, internal fit, fracture strength and mode of fracture of CAD/CAM temporary crowns to direct chairside counterparts. An upper left first premolar Frasaco tooth was prepared for all-ceramic crown. The materials used for comparison were VITA CAD-Temp®, ArtBloc®Temp, PMMA DISK and Acrytemp (control group). The crowns were divided into four groups (n=10). Each crown was investigated for the above parameters. Statistical analysis was performed using SPSS v.20. The average marginal gap, internal gap and fracture strength showed statistically significant difference between groups (p<0.01). The fracture mode showed statistically non-significant difference (p>0.05) among experimental groups. The CAD/CAM temporary crowns demonstrated superior mechanical properties compared to direct handmade counterparts.

Content from these authors
© 2018 The Japanese Society for Dental Materials and Devices