Dental Materials Journal
Online ISSN : 1881-1361
Print ISSN : 0287-4547
ISSN-L : 0287-4547

この記事には本公開記事があります。本公開記事を参照してください。
引用する場合も本公開記事を引用してください。

Comparison of fracture toughness measurements for zirconia materials using two test methods
Jan Ulrich JANSENNina LÜMKEMANNBeatrice SENERBogna STAWARCZYK
著者情報
ジャーナル フリー 早期公開

論文ID: 2018-361

この記事には本公開記事があります。
詳細
抄録

To determine the influence of the fracture toughness (KIC) methods [single-edge-V-notch-beam (SEVNB) and chevron-notch-beam (CNB)] as well as an optional heat treatment on the KIC of three different zirconia generations (1st: ZI, 3rd: FX, 4th: HT). One hundred and twenty specimens each (3×4×45 mm) were fabricated, sintered, notched (n=360) and half of them heat treated before KIC measurements with 4-point-flexural-strength test. SEM images of the notches were recorded. Highest KIC was found for ZI followed by HT and FX. SEVNB resulted in significantly higher KIC than CNB. Heat treatment resulted in decrease for SEVNB and increase for CNB of KIC (except for FX). Groups tested using CNB showed higher reliability of values (Weibull modulus) than tested using SEVNB. SEM images present crack path and fracture surface. Different zirconia materials lead to different KIC values. The test method and a prior heat treatment showed an influence on the KIC values and their reliability.

著者関連情報
© 2019 The Japanese Society for Dental Materials and Devices
feedback
Top