Dental Materials Journal
Online ISSN : 1881-1361
Print ISSN : 0287-4547
ISSN-L : 0287-4547

This article has now been updated. Please use the final version.

Fracture resistance of CAD/CAM restorative materials in mismatched removable partial denture rests: An in vitro experimental and finite element analysis
Keiichiro UCHIKURANatsuko MURAKAMIToshiki YAMAZAKIHuaxin LYUKohji NAGATAMasahiro ONANaohiko IWASAKIHidekazu TAKAHASHINoriyuki WAKABAYASHI
Author information
JOURNAL FREE ACCESS Advance online publication

Article ID: 2021-224

Details
Abstract

To evaluate the fracture resistance of computer-aided design and computer-assisted manufacturing restorations as the abutment of removable partial dentures, experimental blocks, with the rest seat made of feldspar, hybrid resin composite, lithium disilicate glass ceramic, or zirconia, were subjected to loading by a metallic occlusal rest. The rest contacted the rest seat with an accurate fit and two mismatch contact conditions: bottom and sidewall contact. Zirconia exhibited the highest fracture load, and the fracture load of the accurate fit was significantly higher than that of the sidewall contact (p<0.05) and insignificantly higher than that of the bottom contact (p>0.05). A finite element analysis of the sidewall contact revealed a higher tensile stress concentration at the bottom of the rest seat than the other contact conditions. The mismatch between the rest and the restoration reduced fracture resistance, while zirconia as the abutment withstood the average occlusal force of the posterior region.

Content from these authors
© 2022 The Japanese Society for Dental Materials and Devices
feedback
Top