Dental Materials Journal
Online ISSN : 1881-1361
Print ISSN : 0287-4547
ISSN-L : 0287-4547

この記事には本公開記事があります。本公開記事を参照してください。
引用する場合も本公開記事を引用してください。

Fracture strength of implant-supported hybrid abutment crowns in premolar region fabricated using different restorative CAD/CAM materials
Ryoki TAKANOJunichi HONDATatsuro KOBAYASHIKei KUBOCHIHiroki TAKATAFutoshi KOMINE
著者情報
ジャーナル フリー 早期公開

論文ID: 2022-165

この記事には本公開記事があります。
詳細
抄録

The present study investigated the fracture strength of hybrid abutment crowns (HACs) in the premolar region that were fabricated with different restorative computer-aided design/computer-aided manufacturing (CAD/CAM) materials. The abutment-implant structures were randomly assigned into four groups (n=11 per group): bi-layered zirconia restorations (BL), translucent zirconia (4Y-PSZ) restorations (TZ), lithium disilicate ceramic restorations (LD), and dispersed nanoparticle-filled composite resin restorations (CM). All restorations were adhesively bonded to the titanium abutments. After the restoration-abutment complex was tightened onto the implant, the fracture strength was measured. The TZ (2.06 kN) and LD (1.87 kN) groups had significantly higher median fracture strengths than the BL (1.12 kN) and CM (1.10 kN) groups. In terms of fracture resistance, the 4Y-PSZ and lithium disilicate ceramic monolithic restorations would be superior to bi-layered 3Y-TZP and composite resin monolithic restorations for HACs in the premolar region.

著者関連情報
© 2023 The Japanese Society for Dental Materials and Devices