Mechanical properties and degree of conversion of resin-based core build-up materials and short fiber-reinforced flowable resin-based composite
Abdulrahman ALSHABIBCarlos A. JURADOFrancisco X. AZPIAZU-FLORESKhalid ALDOSARYAkimasa TSUJIMOTOHamad ALGAMAIAH
Author information
JOURNAL FREE ACCESS Advance online publication

Article ID: 2023-207

Details
Abstract

To evaluate the degree of conversion (DC), surface hardness (SH), and flexural strength (FS) of resin-based core build-up materials. Core build-up materials used were: MultiCore Flow (MCF); Activa (ACT); Core-X Flow (CXF); and everX flow (EVX), and DC, SH and FS were measured. An increase of DC was identified for all materials post-cure, except for EVX. The DC change percentage ranged from 5%–33%, and EVX was displayed the greatest DC rate. All materials displayed an SH increase after 30 days and the greatest increase was observed in ACT. At 1 h, the SH of EVX and CXF was different from the other materials. At 30 days, MCF displayed the greatest SH. All materials displayed an increase in their FS after 30 days except for EVX, and ranging 3%–36% were noticed. Differences observed between materials, thus clinician should be acquainted mechanical properties of these materials to ensure the success of the restorations.

Content from these authors
© 2024 The Japanese Society for Dental Materials and Devices

This is an open access article under the CC BY license
https://creativecommons.org/licenses/by/4.0/