Dental Materials Journal
Online ISSN : 1881-1361
Print ISSN : 0287-4547
ISSN-L : 0287-4547
Effect of Denture Cleaner using Ozone against Methicillin-resistant Staphylococcus aureus and E. coli T1 Phage
Hiroshi MURAKAMIMiho MIZUGUCHIMasami HATTORIYutaka ITOTatsushi KAWAIJiro HASEGAWA
著者情報
キーワード: Ozone, MRSA, E Coli T1 Phage
ジャーナル フリー

2002 年 21 巻 1 号 p. 53-60

詳細
抄録
We examined the bactericidal and virucidal effectiveness of a denture cleaner that uses ozone (ozone concentration, 10ppm) against methicillin-resistant Staphylococcus aureus (MRSA) and T1 phage, respectively- In the bactericidal activity test, with the ozone supply turned on, the number of bacteria was 3.1×103CFU/mL at the beginning of the experiment, fell to 1.0×100 CFU/mL 10min later, and was 1.0×100CFU/mL or less afterwards. In contrast, when the ozone supply was cut off (air bubble only), the number of bacteria was 3.4×103CFU/mL at the beginning of the experiment, and had fallen to 3.0×103CFU/mL 60min later (no statistically significant difference). In the virucidal activity test, the number of phages was 1.2×106PFU/mL before ozone treatment, fell to about 1/10 of that number 10min later, and was 6.1×100 PFU/mL 40min later.
These results indicate that the use of ozone in this denture cleaner is effective against MRSA and viruses.
著者関連情報
© The Japanese Society for Dental Materials and Devices
前の記事 次の記事
feedback
Top