Abstract
This study evaluated the microhardness and Young's modulus of a photocurable bonding resin, Clearfil SE Bond (SE), cured with four curing units at different distances. The curing units used were: Candelux (Quartz-tungsten halogen), Lux-O-Max (Blue light emitting diode), Arc-light (Plasma-arc), and Rayblaze (Metal halide). Discs of bonding resin were prepared using vinyl molds and were photocured at the top surface with light tip at three different distances (contact, 2 and 4mm). After 24 hours of storage in water at 37°C, the specimens were sectioned into halves, embedded in epoxy resin, and polished. The microhardness and Young's modulus of this bonding resin were measured using a nanoindentation tester. Six specimens were prepared for each group. The data was statistically analyzed using two-way ANOVA test and Tukey multiple comparison test (p<0.01). The microhardness of SE was affected by light source and distance, as was Young's modulus. Candelux and Rayblaze presented the highest hardness and Young's modulus results. Both properties presented high values when the curing unit tip was maintained in contact with the irradiated surface. Increasing the distance between the curing unit tip and the irradiated surface decreased the hardness and Young's modulus of SE.