Dental Materials Journal
Online ISSN : 1881-1361
Print ISSN : 0287-4547
ISSN-L : 0287-4547
Effect of Test Method on Flexural Strength of Recent Dental Ceramics
Jingyue JINHidekazu TAKAHASHINaohiko IWASAKI
著者情報
ジャーナル フリー

2004 年 23 巻 4 号 p. 490-496

詳細
抄録
The purpose of the present study was to evaluate the relationships among three flexural strengths of recent dental ceramics using 3-point and 4-point bending tests and biaxial flexural test. Three brands of porcelain for veneering (d⋅SIGN, Supper porcelain AAA, Vintage Hallo), two injectable ceramics (Empress 2, OPC 3G), and one castable ceramic (Crys-Cera) were used. Twenty bar-shaped and 10 disc-shaped specimens of each ceramic type were prepared according to manufacturers' instructions, polished, and subjected to 3-point and 4-point bending tests and biaxial flexural test, respectively. Three flexural strengths for each ceramics were compared using one-way analysis of variance and Tukey comparison, and also investigated by Weibull analysis. The biaxial flexural strength and 3-point bending strength of all ceramics, except OPC 3G and Crys-Cera, were significantly greater than the corresponding 4-point bending strength. As for OPC 3G and Crys-Cera, their biaxial flexural strengths were significantly greater than their 3-point bending strengths, which is contrary to the other ceramics. The Weibull moduli ranged from 6.6 to 20.8. The Weibull moduli of examined ceramics, except Crys-cera, were statistically insignificant regardless of test methods.
著者関連情報
© The Japanese Society for Dental Materials and Devices