Dental Materials Journal
Online ISSN : 1881-1361
Print ISSN : 0287-4547
ISSN-L : 0287-4547
Fabrication of Hydroxyapatite Block from Gypsum Block Based on (NH4) 2HPO4 Treatment
Yumiko SUZUKIShigeki MATSUYAKoh-ichi UDOHMasaharu NAKAGAWAYoshihiro TSUKIYAMAKiyoshi KOYANOKunio ISHIKAWA
著者情報
ジャーナル フリー

2005 年 24 巻 4 号 p. 515-521

詳細
抄録

The aim of this study was to evaluate the feasibility of fabricating low-crystalline, porous apatite block using set gypsum as a precursor based on the fact that apatite is thermodynamically more stable than gypsum. When the set gypsum was immersed in 1mol/L diammonium hydrogen phosphate aqueous solution at 100°C, it transformed to low-crystalline porous apatite retaining its original shape. The transformation reaction caused a release of sulfate ions due to an ion exchange with phosphate ions, thus leading to a decrease in the pH of the solution. Then, due to decreased pH, dicalcium phosphate anhydrous—which has similar thermodynamic stability at lower pH—was also produced as a by-product. Apatite formed in the present method was low-crystalline, porous B-type carbonate apatite that contained approximately 0.5wt% CO3, even though no carbonate sources—except carbon dioxide from air—were added to the reaction system. We concluded therefore that this is a useful bone filler fabrication method since B-type carbonate apatite is the biological apatite contained in bone.

著者関連情報
© The Japanese Society for Dental Materials and Devices
前の記事 次の記事
feedback
Top