Dental Materials Journal
Online ISSN : 1881-1361
Print ISSN : 0287-4547
ISSN-L : 0287-4547
Radiographic Observation of the Internal Porosities in Castings of High Fusible Base Alloy
Haruyuki KAWAHARANobuhiro ISHIZAKITakatoshi MAEDAHiroki SAKAE
Author information
JOURNAL FREE ACCESS

1984 Volume 3 Issue 1 Pages 71-84,129

Details
Abstract
In order to investigate internal porosities of high fusible base alloy castings, non-destructive inspection was carried out by radiographic method with an X-ray unit. Test samples were made of cobalt-chromium and nickel-chromium alloys, and shaped into 13 steps of wedge type castings with the minimum thickness of 0.35mm and maximum thickness of 4.55mm in an incremental increase of 0.35mm. It was found that the X-ray unit could provide clear radiographs. The internal porosities of metal denture frame, crown-bridge and dental implant made of base alloy were easy to interpret by setting the exposure time to 90 seconds with three tube voltages of 50, 60 and 70kVp according to thickness of castings.
Content from these authors
© The Japanese Society for Dental Materials and Devices
Previous article Next article
feedback