Polypyrrole/CuBi2O4 Nanosheets for Sensitive Electrochemical Determination of Benzoic Acid
J. F. Huang, F. H. Tao, F. Y. Li, Z. Y. Cai, L. Z. Pei
著者情報
ジャーナル オープンアクセス

2023 年 21 巻 1 号 p. 1-8

詳細
抄録

Polypyrrole (PPy)/CuBi2O4 nanosheets (NSs) were prepared by an in situ polymerization process and the NS-modified glassy carbon electrode (GCE) for electrochemical determination of benzoic acid was studied. The structure, morphology, and functional groups of the PPy/CuBi2O4-NSs were analyzed by X-ray diffraction, transmission electron microscopy (TEM), high-resolution TEM, and Fourier transform infrared spectroscopy. The obtained NSs contain a tetragonal CuBi2O4 phase, and nanoscale PPy particles attach to the surface of the NSs. The electrochemical responses of the PPy/CuBi2O4-NS-modified GCE in 0.1 M KCl solution with benzoic acid were investigated by the cyclic voltammetry (CV) and electrochemical impedance spectroscopy. An irreversible CV peak is located at −0.84 V on the PPy/CuBi2O4-NS-modified GCE in 2 mM benzoic acid and 0.1 M KCl solution. The intensities of the CV peaks show linear variation with increasing the scan rate and concentration of benzoic acid. The linear range is 0.001−2 mM with a detection limit of 0.52 μM. The PPy/CuBi2O4-NS-modified GCE shows high stability and reproducibility. The prepared PPy/CuBi2O4-NSs have great promise in the electrochemical detection of benzoic acid.

Fullsize Image
著者関連情報

This article is licensed under a Creative Commons [Attribution 4.0 International] license.
https://creativecommons.org/licenses/by/4.0/