IEICE Electronics Express
Online ISSN : 1349-2543
ISSN-L : 1349-2543
LETTER
TID characterization of COTS parts using radiotherapy linear accelerators
Oscar GutiérrezManuel PrietoAlberto Sánchez-ReyesAlberto Gómez
著者情報
ジャーナル フリー

2019 年 16 巻 7 号 p. 20190077

詳細
抄録

Ionizing radiation can disturb electrical and electronic devices. These devices need to be tested and qualified to operate under special environment conditions such those present in nuclear or space applications. Radiation effects must be considered when designing systems that must have high mean time between failures and are exposed to radiation. This paper shows how common radiotherapy linear accelerators (LINAC) can be used to characterize the Total Ionizing Dose (TID) effects on electronic devices. This work presents the principal radiation-induced effects on a Raspberry Pi Compute Module board, as good representative of typical Commercial Off-The-Shelf components. The Monte Carlo method used and the procedure for TID characterization are shown.

著者関連情報
© 2019 by The Institute of Electronics, Information and Communication Engineers