A comparison of modified periodogram and Blackman-Tucky methods for wideband receiver applications
Jason PenningtonChi-Hao Cheng
著者情報
ジャーナル フリー

2021 年 18 巻 4 号 p. 20200453

詳細
抄録

A wideband receiver is designed to detect signals over a broad bandwidth. To increase the receiver’s capability of detecting multiple signals, it is a common practice to apply a window to reduce spectral leakage. The modified periodogram applies a window before auto-correlation and Blackman-Tucky method applies the window after auto-correlation. To the best of authors’ knowledge, no one has compared the performance difference in the context of wideband receiver applications. This study finds that the modified periodogram can better enable a receiver to detect multiple signals with a significant power difference at the expense of reduced frequency resolution and sensitivity.