IEICE Electronics Express
Online ISSN : 1349-2543
ISSN-L : 1349-2543

This article has now been updated. Please use the final version.

Analysis of the residual error due to mechanical stress in BJT-based CMOS temperature sensors
Dexin KongFengqi Yu
Author information
JOURNAL FREE ACCESS Advance online publication

Article ID: 14.20170318

Details
Abstract

It is widely known that the inaccuracy of BJT-based CMOS temperature sensors is higher at high temperature range, which greatly limits their application. In this paper, the characteristic of the error after calibration is analyzed. Through the experiments, we discover that the cause of this problem is not circuit related, instead it is process related, which is the mechanical stress generated during manufacturing and packaging. Experimental results show that an accuracy of −0.5 ~ 2 °C can be obtained for the calibrated non-epoxy sensors from −40 °C to 120 °C.

Content from these authors
© 2017 by The Institute of Electronics, Information and Communication Engineers