グランド再生可能エネルギー国際会議論文集
Online ISSN : 2434-0871
Japan council for Renewable Energy(2018)
会議情報

STRING FAILURE DETECTION FOR LARGE SCALE PHOTOVOLTAIC SYSTEM BY USING NAMEPLATE VALUE AND MEASURED STRING CURRENT AND MODULE VOLTAGE
*Tomoka UchiyamaYuzuru Ueda
著者情報
会議録・要旨集 フリー

p. 36-

詳細
抄録
In large-scale PV systems, remote monitoring is conducted in order to reduce the cost of on-site inspection. We propose a remote strings fault detection method for PV systems. By measuring the string current and module voltage of each strings, the proposed method can detect fault such as partial disconnection in the string. The current / voltage measured at the power conditioner and the threshold value obtained by simulation are used for detection. We verified the accuracy of proposed method using an actual large scale PV system in Japan and detected a string that may contain a malfunctioning module.
著者関連情報
© 2018 Japan Council for Renewable Energy (JCRE)