日本地熱学会誌
Online ISSN : 1883-5775
Print ISSN : 0388-6735
ISSN-L : 0388-6735
論文
垂直型地中熱交換井への注水が熱交換能力に与える影響に関してのフィールド試験による検討
駒庭 義人藤井 光前原 隆広長 直勝
著者情報
ジャーナル フリー

2013 年 35 巻 4 号 p. 137-148

詳細
抄録
In this study, thermal response tests (TRTs) with water injection into a ground heat exchanger (GHE) were conducted to evaluate how vertical water flow in the well influences the heat exchange performance. The GHE used for TRTs has slotted screen pipes with depths from 41 m to 71 m, and natural groundwater level is 14.5 m. Hydraulic conductivity of the reservoir is 6.35×10&sup-6; m/s. Thermal tracer tests were first carried out for understanding how deep the injected water in the well runs out into fractures. The results of thermal tracer tests showed that the injected water runs out into fractures with depths from 57 m to 64 m. Thus, injected water in the well generates vertical water flow in this well. TRTs were then conducted on 4 different patterns of water injection rate; no injection (TRT-0), 5 l/min (TRT-5), 10 l/min (TRT-10) and 20 l/min (TRT-20). Temperatures of injected water were stable through each TRT. Averaged temperature of injected water in the case of TRT-5, TRT-10 and TRT-20 was 20.9°C as against 15.5°C for temperature of ground. The results of TRTs showed that the averaged temperature of heat medium during the circulation of between 43 to 46 hours in the case of 20 l/min injection is 5°C lower than ones in the case of no injection. Therefore, it can be said that vertical water flow induced by water injection into the GHE can enhance heat exchange performance of the GHE drilled throughpermeable layers.