2009 年 129 巻 12 号 p. 2102-2107
From an anatomically-based Japanese model of three-year-old child with a resolution of 1 mm, we developed a nine-month Japanese infant with linear shrink. With these models, we calculated the whole-body average specific absorption rate (WBA-SAR) for plane-wave exposure from 0.1 to 6 GHz. A conservative estimate of the WBA-SAR was also investigated by using three kinds of simple-shaped models: cuboid, ellipsoid and spheroid, whose parameters were determined based on the above three-year-old child model. As a result, the cuboid and ellipsoid were found to provide an overestimate of the WBA-SAR compared to the realistic model, whereas the spheroid does an underestimate. Based on these findings for different body models, we have specified the incident power density required to produce WBA-SAR of 0.08 W/kg, which is the basic restriction for public exposure in the guidelines of International Commission on Non-Ionizing Radiation Protection.