電気学会論文誌A(基礎・材料・共通部門誌)
Online ISSN : 1347-5533
Print ISSN : 0385-4205
ISSN-L : 0385-4205
論文
ESDガンの接触放電に対する放電電流のIEC規格波形と周波数スペクトル
髙 義礼戸谷 史彦藤原 修石上 忍山中 幸雄
著者情報
ジャーナル フリー

2015 年 135 巻 10 号 p. 592-597

詳細
抄録
In 2008, International Electrotechnical Commission (IEC) prescribed an immunity test (IEC61000-4-2) of electronic equipment against electrostatic discharges (ESDs), and provided a theoretical ESD current based on a Heidler's formula. For the current waveform, however, not the whole waveform but only the rise time, the first peak, and the current values at 30 ns and 60 ns are specified in the time domain along with their variability so that a commercially available ESD generator (ESD gun) shall be calibrated by checking whether or not the injected current onto an IEC recommended current target meets the IEC specification. In this study, to propose in the frequency domain the allowable variability of IEC specified current waveforms, we calculated the frequency spectra of theoretical current waveforms obtained by changing the parameters in the Heidler's formula, which were compared with those of discharge currents measured for contact discharges of commercially available ESD guns onto the IEC target. Results enabled us to give the allowable variability in the current spectra with respect to the theoretical current waveform, which is from -5 dB to +4 dB up to 400 MHz and from -6 dB to +8 dB over 400 MHz, while the measured waveforms that meet the IEC standard in the time domain have the spectra greater than +8 dB over 1 GHz due to the distortion of the current rising waveforms, although they fall in the allowable range below 1 GHz.
著者関連情報
© 2015 電気学会
前の記事 次の記事
feedback