静電気試験器の気中放電に対する火花長測定法の精度検証
高 義礼川又 憲藤原 修
著者情報
ジャーナル フリー

2016 年 136 巻 6 号 p. 376-377

詳細
抄録
We previously developed a measurement system of spark length in air discharges of electrostatic generator (ESD gun) using laser Doppler effects. The spark length can be obtained through time integration of the velocity data from spark occurrence time to collision time when moving the grounded plate to the ESD gun, while the measurement accuracy has not yet been validated. In this study, we compared the measured spark lengths using two methods that identify the collision time by detecting field emission and by detecting discharge of gun remaining charges, respectively.