タングステン接点によるハイブリッド直流遮断器のアークレス転流
早川 達也中山 恭太郎安岡 康一
著者情報
ジャーナル フリー

2017 年 137 巻 7 号 p. 416-421

詳細
抄録

A hybrid circuit breaker comprises power semiconductor devices and a varistor connected in parallel with an electrical contact. In this study, we use SiC-MOSFET and the contact made from tungsten for hybrid DC circuit breaker to implement arcless commutation. We conducted current commutation experiment at the condition of DC 50 V, 150 A. As a result, contact erosions which have a depth of several tens of micrometer are observed in the case of commutation by arc discharge for a few microseconds. In contrast, the erosion was not observed completely in the case of arcless commutation.

著者関連情報
© 2017 電気学会