2020 Volume 140 Issue 11 Pages 862-873
A number of machines have been fitted with electric motors and their inverters. To reduce the space of the motors and inverters, motors with two controllable rotors using a six-phase inverter have been proposed. However, the winding factor of three-phase and six-phase rotors in a conventional winding arrangement are 0.87 and 0.50, respectively. In order to improve the winding factor of the motor, we propose a novel winding arrangement and verify its effectiveness using finite element analysis.
The transactions of the Institute of Electrical Engineers of Japan.C
The transactions of the Institute of Electrical Engineers of Japan.B
The transactions of the Institute of Electrical Engineers of Japan.A
The Journal of the Institute of Electrical Engineers of Japan