This paper presents a phase-shift control method of a triple-active-bridge converter for distributed power supply systems with multiple batteries. The experimental results show that the reactive power through the transformer can be suppressed under a wide range of conditions. The proposed phase-shift control method improves the light load loss at 500W by approximately 30% compared to the conventional method. In addition, according to the power-transmission characteristics of the proposed method, for applications in which a voltage source connected to an input port is attached and detached, the power supply and demand can be adjusted between each output port while gradually lowering the charge of the input port by utilizing the characteristics of the charging operation. Therefore, the converter can continue to operate regardless of the attachment and detachment of the input port-voltage source.