IEEJ Journal of Industry Applications
Online ISSN : 2187-1108
Print ISSN : 2187-1094
ISSN-L : 2187-1094
Selected and English Translation Paper of IEEJ Trans. IA
Theoretical Consideration of the Long-length Primary Loop used in SCMaglev's DWPT System
Keisuke YamamotoJun EnomotoShunsaku KogaJunichi Kitano
著者情報
ジャーナル フリー

2024 年 13 巻 5 号 p. 580-586

詳細
抄録

The primary loop of the SCMaglev's DWPT system has several distinctive features compared to other DWPT systems. These include its length, order of several kilometers, its installation position close to the concrete roadbed and its working frequency near 10kHz. These were almost no findings and experiences regarding electric constants required for designing the electric resonance, theoretical considerations have been conducted to determine the constants, inductance and stray capacitance. The value obtained can be calculated using simplified methods and are close to the results obtained from the field test.

著者関連情報
© 2024 The Institute of Electrical Engineers of Japan
前の記事 次の記事
feedback
Top