IEEJ Journal of Industry Applications
Online ISSN : 2187-1108
Print ISSN : 2187-1094
ISSN-L : 2187-1094
Special Issue Paper
Effect of Cleaning Level on Topology Optimization of Permanent Magnet Synchronous Generator
Takeo IshikawaTaiki WatanabeNobuyuki Kurita
著者情報
ジャーナル フリー

2017 年 6 巻 6 号 p. 416-421

詳細
抄録

We propose a topology optimization method that incorporates the concept of the cluster and cleaning method in a genetic algorithm. This method can be used to design a rotor structure with high output power and low permanent magnet volume from an empty space. In this study, the effect of the level of the cleaning method on the obtained rotor structure is investigated. A permanent magnet synchronous generator is designed using the optimal level of the cleaning method. This generator has higher output power characteristic with low permanent magnet volume than a generator used in Prius, which is a general hybrid vehicle.

著者関連情報
© 2017 The Institute of Electrical Engineers of Japan
前の記事 次の記事