IEEJ Journal of Industry Applications
Online ISSN : 2187-1108
Print ISSN : 2187-1094
ISSN-L : 2187-1094

この記事には本公開記事があります。本公開記事を参照してください。
引用する場合も本公開記事を引用してください。

Two-Battery HEECS Inverter with over 99.7% Efficiency at 2.2kW Output and Measurement Accuracy Based on Loss Breakdown
Atsuo KawamuraSatoshi NakazakiShogo ItoSakahisa NagaiHidemine Obara
著者情報
ジャーナル フリー 早期公開

論文ID: 20001291

この記事には本公開記事があります。
詳細
抄録

A DC-AC conversion efficiency of over 99.7% is experimentally measured using a two battery high efficiency energy conversion system (HEECS) inverter. The accuracy of the efficiency measurement is evaluated by two methods: the direct measurement method and the loss breakdown method. After several measurements, calculations and analyses it is concluded that the measurement error based on the loss breakdown method is 0.04%.

著者関連情報
© 2020 The Institute of Electrical Engineers of Japan
feedback