整数計画法を用いた電気機器の非侵入型稼働状態モニタリング
稲垣 伸吉江上 司鈴木 達也中村 久栄伊藤 公一
著者情報
ジャーナル フリー

2008 年 128 巻 11 号 p. 1386-1392

詳細
抄録
This paper presents a new nonintrusive appliance load monitoring technique based on the integer programming. Nonintrusive appliance load monitoring is a problem to identify the operating conditions of the electric appliances in a house only by observing the overall load current and voltage. Since the overall load current is expressed as a superposition of each current of the operating appliance, the monitoring problem can be formulated as an integer quadratic programming problem by expressing the operating conditions as integer variables. This problem is solvable with sufficiently small computational burden thanks to the recent development of the commercial software. The proposed method does not require the relearning even when a new appliance is installed in the house. Furthermore, the proposed formulation is applicable to cases that some appliance has multiple modes, and cases that some same-type appliances operate simultaneously. Usefulness of the proposed technique is verified through some experimental results.