電気学会論文誌B(電力・エネルギー部門誌)
Online ISSN : 1348-8147
Print ISSN : 0385-4213
ISSN-L : 0385-4213
論文
モーリレー不要動作による事故波及の回避を考慮した電圧・熱容量TTC算出法の提案
餘利野 直人造賀 芳文末成 展康川本 晃亘李 生虎
著者情報
ジャーナル フリー

2010 年 130 巻 1 号 p. 100-105

詳細
抄録
This paper proposes a new computation method for Total Transfer Capability (TTC) with respect to thermal and voltage magnitude limits. TTC is formulated as an optimization problem and solved by The Primal-Dual Interior Point Method (PDIPM). In stressed power system, mho relays are possible factors for causing cascading failures because of their unnecessary operations caused by decrease in voltages in heavy load conditions. Therefore, in order to consider mho relay characteristics, the relay operating conditions are taken into account in the optimization problem as constraints to compute TTC. The effectiveness of the proposed method is demonstrated through IEEE 57 bus system model.
著者関連情報
© 電気学会 2010