電気学会論文誌B(電力・エネルギー部門誌)
Online ISSN : 1348-8147
Print ISSN : 0385-4213
ISSN-L : 0385-4213
特集論文
CVケーブル水トリー進展に伴うインパルス有害特性評価
中出 雅彦永田 健一阿部 和俊
著者情報
ジャーナル フリー

2014 年 134 巻 8 号 p. 633-638

詳細
抄録
The relationship of AC breakdown performance and water tree has been reported. This time, using aged XLPE cables with some protrusion on the outer semiconductor layer, we evaluated the relationship of water tree growth and impulse breakdown performance. As a result, in case of XLPE cables without waterproof layer, it was confirmed that the impulse breakdown performance decreased because of water tree, and we got possibility the impulse breakdown performance depended on the progress of water tree growth. In addition, it might decrease to the around LIWV. On the other hand, in case of XLPE cables with waterproof layer, though water tree progressed slowly, the impulse breakdown performance was maintained for a long time. In other words, the effect of waterproof was proved. Even if XLPE cables with waterproof layer have big protrusion, most of water tree started from the protrusion does not grow up. But, if water tree grows up, it may largely reduce the impulse breakdown performance of XLPE cables with waterproof layer.
著者関連情報
© 2014 電気学会
前の記事 次の記事
feedback
Top