電気学会論文誌B(電力・エネルギー部門誌)
Online ISSN : 1348-8147
Print ISSN : 0385-4213
ISSN-L : 0385-4213
特集論文
Upward Lightning Attachment Analysis on Wind Turbines and Correlated Current Parameters
Stephan VogelMasaru IshiiMikihisa SaitoDaisuke Natsuno
著者情報
ジャーナル フリー

2018 年 138 巻 5 号 p. 327-332

詳細
抄録

This work provides insight in the attachment characteristics of upward initiated lightning discharges to wind turbines and their possible consequences for the lightning protection of wind turbine blades. All discharges were recorded at the Japanese coast of the Sea of Japan which is known for intense upward lightning activity. 172 video recordings of lightning discharges on rotating wind turbines are analysed and attachment angle, detachment angle, and the resulting angular displacement were determined. A classification between self-initiated and other-triggered upward lightning events is performed by means of video analysis. The results reveal that the majority of discharges are initiated when the wind turbine blade is aligned vertically; however, also lightning attachments to horizontal blades are reported. Horizontal attachment (or a slightly inclined blade state) is often related with a triggered lightning event prior to the discharge. There are about twice as many lightning attachments during the ascending blade movement compared to the descending blade movement. Furthermore, a comparison between current parameters of upward lightning flashes during stationary and rotating wind turbine operation reveal no substantial difference between the two operational states.

著者関連情報
© 2018 by the Institute of Electrical Engineers of Japan
前の記事 次の記事
feedback
Top