超音波振動を用いた液滴操作デバイスにおける液滴操作条件の検討
大西 健一神田 岳文小川 尚哉鈴森 康一
著者情報
ジャーナル フリー

2016 年 136 巻 8 号 p. 348-356

詳細
抄録
In this study, we have fabricated a droplet manipulation device which has a microchannel oscillated by piezoelectric actuator. This device can manipulate droplets by producing a pressure distribution of a standing acoustic field caused by ultrasonic vibration in the microchannel. The manipulated droplet's size has been estimated from the relationship between acoustic force and viscous force. The device has been designed by using a finite element method analysis. Fabricated device has been evaluated by observing droplets in manipulation experiment and measuring a manipulated droplet's distribution. When n-dodecane was used as dispersed phase, this device can manipulate a droplet whose diameter is larger than 20µm when the applied voltage and the driving frequency were 80Vp-p and 2.25MHz. When Silicone oil was used as dispersed phase, the manipulated droplets diameter was larger than 15µm. From these results, we have indicated that the microchannel device can manipulate droplets by using ultrasonic vibration.