IEEJ Transactions on Sensors and Micromachines
Online ISSN : 1347-5525
Print ISSN : 1341-8939
ISSN-L : 1341-8939
Special Issue Paper
Initial Evaluation of the Continuous Sampling Method using Liquid-gate Realized by Porous Membrane and Hydrophilic/Hydrophobic Interface
Kenshiro SakataYang LuKatsuo MogiTakatoki Yamamoto
Author information
JOURNAL FREE ACCESS

2017 Volume 137 Issue 6 Pages 169-173

Details
Abstract

There are various potentially hazardous particles dispersed in various environment, such as virus, exhaust gas, PM 0.1 and 2.5, endospore of bacteria, etc. One of the key issues to monitor the presence of such the particles is a development of particle sensor, which should work continuously for a long time. In order to realize such type of sensor, we have proposed and experimentally demonstrated a clogging-free sampling method for continuous sampling and sensing operation by applying liquid-gate concept. We fabricated a test device and evaluated using carbon toner as a model of carbon particulate in atmospheric air. As a result, it was still primitive, we successfully proofed the concept of liquid gate sampling as expected.

Content from these authors
© 2017 by the Institute of Electrical Engineers of Japan
Previous article Next article
feedback