2022 年 142 巻 2 号 p. 17-20
In this paper, we report the development of time-delay analysis method of inductance and capacitance for microfluidic circuit. The sensor used in this method is composed of the sensing inductor (SI) and the sensing capacitor (SC) with a microfluidic circuit. This sensor measures inductance and capacitance in a time difference by delaying with microfluidic circuit. We confirmed that SI and SC have different responses to conductive and dielectric solution. This research is expected to be applied to the combined analysis of liquid samples.