Calibration Using Cylindrical Artifacts for 3D Laser Measurement System
Kazuhiro Enami
著者情報
ジャーナル オープンアクセス

2015 年 9 巻 5 号 p. 546-550

詳細
抄録

We propose a new calibration method for 3D laser measurement systems used for inspecting the insides of industrial parts such as vessels and pipes. We developed the proposed calibration system using a cylindrical artifact such that the calibration is simple and easy to perform. We simulated and analyzed the proposed cylindrical artifact calibration method and the results demonstrate its adequacy.