Hydrographic Model Test on Prevention against Vortex Occurrence for Vertical Bulb Turbine
Shoichi YamatoShogo NakamuraAkinori Furukawa
著者情報
ジャーナル フリー

2009 年 2 巻 4 号 p. 418-425

詳細
抄録
A vertical bulb turbine unit with elbow type draft tube has been developed due to avoidance of complicated assembling and long standstill period at overhaul in comparison with conventional horizontal bulb turbine unit. Before designing the prototype vertical bulb unit, a hydrographic model test was carried out to establish the ideal design concept for this innovative generating unit.
Froude similarity is not available for vortex occurrence. Consequently, an intake structure without air entraining vortices under all the flow conditions is developed, and it is confirmed that the surge wave at load rejection is not affected harmful influence for other constructions.
著者関連情報

この記事は最新の被引用情報を取得できません。

© 2009 Turbomachinery Society of Japan, Korean Fluid Machinery Association, Chinese Society of Engineering Thermophysics, IAHR